XCITE 1100 Field Test Series

The Xcite 1100 Field Test Series uses the same Exciter Heads and Master Controller as the 1100 Laboratory Series but replaces the 5 GPM 3-Phase Hydraulic Power Supply with a field portable 1.2 GPM Single Phase Power Supply. While providing the same 3000 PSI pressure, the field test unit is switch selectable from 110 V (20 A) to 220 V (10 A) single phase power.

This simplified power requirement along with the packaging of the unit in a roto-molded shipping case provide for ease of modal testing in remote areas of your facility and allows air shipment to off site test destinations. The 1100Field Test Series is used in the power and natural gas distribution industries as well as on shipboard structure borne noise path identification.

Xcite 1100-4-FT System Xcite 1100-6-FT System Xcite 1100-7-FT System
Exciter Head 1106-4-T/C 1107-4-T/C 1114-4-T/C
Hydraulic Power Supply 1001P   1.2GPM (5 l/m) 1001P   1.2GPM (5 l/m) 1001P   1.2GPM (5 l/m)
Master Controller 1104-MOD4 1104-MOD4 1104-MOD4
Static Force 1,000 lb (4,450 N) 1,000 lb (4,450 N) Total Static & Dynamic
Dynamic Force 1,000 lb (4,450 N) 1,000 lb (4,450 N) Force = 1,000 lb (4,450 N)
Stroke 1.0 in (25 mm) 2.0 in (50 mm) 1.0 in (25 mm)
Rod .75 in (18 mm) .75 in (18 mm) .75 in (18 mm)
Bore 1.0 in (25 mm) 1.0 in (25 mm) 1.0 in (25 mm)
Thread .38 – 24 .38 – 24 .38 – 24
Load Cell 2,500 lb (11,125 N) 2,500 lb (11,125 N) 2,500 lb (11,125 N)
LVDT 1.0 in (25 mm) 2.0 in (50 mm) 1.0 in (25 mm)
Exciter Design Single Ended Single Ended Double Ended
Manual
Xcite 1100-6-FT System Manual
Xcite 1100-7-FT System Manual

Specifications

Xcite 1100 Field Test Series
Xcite 1100 Field Test Series
Exciter Head A B C D E F G H I
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in(dia)
mm(dia)
in(dia)
mm(dia)
1106-4-T/C
6.12
153
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7
1107-4-T/C
7.12
178
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7
1114-4-T/C
8.78
220
0.60
15
3.12
78
3.75
94
1.38
35
1.12
28
2.00
50
2.75
69
0.28
7
Xcite 1100-4 Field Test System

This system consists of the 1106-4-T/C Exciter Head, 1001P Hydraulic Power Supply and the 1104-MOD4 Master Controller.

Xcite 1100-6 Field Test System

This system consists of the 1107-4-T/C Exciter Head, 1001P Hydraulic Power Supply and the 1104-MOD4 Master Controller.

Xcite 1100-7 Field Test System

This system consists of the 1114-4-T/C Exciter Head, 1001P Hydraulic Power Supply and the 1104-MOD4 Master Controller.

Note: The above force curve is for the Xcite 1114 Head used in Tension/Compression mode with ZERO STATIC FORCE and the load cell rigidly connected to the structure for “PUSH/PULL” operation. In Compression mode only with 500 lbs of Static Force the curves are derated to a maximum of 400-500 lbs Peak Dynamic. (Depending on the structure stiffness of the test article).