Hydraulic Power Supply

The Hydraulic Power Supply furnishes the Exciter Head with its hydraulic pressure, flow and filtration requirements. Xcite Hydraulic Power Supplies present a unique approach to meeting the fluid power requirements of the exciter heads. Each unit is transportable and self-contained to permit use at virtually any test site, yet its low noise characteristics make it equally suited for laboratory use. Power supply control is located on the Master Controller for ease of use. All Xcite power supplies furnish 3,000 PSI of pressure and are available in models ranging from 1 GPM to 30 GPM.

  • Transportability

  • Quiet operation

  • Pressure compensation and variable volume; provides energy consumption because it supplies only the flow demanded by the Exciter Head

  • Housed in rugged, wheeled cabinet

  • Low maintenance

  • Operation features; 3-phase power sequence indicator, temperature and filtration warning lights

  • Automatic shutdown on over-temperature and low oil

  • Polarized quick disconnects

  • Available in air or water cooled models

  • Available in 110V & 220V, 380V or 440V 3-phase models

  • 3 micron filtration

1001P Field Test Hydraulic Power Supply
1001P Field Test HPS

The 1001P Hydraulic Power Supply is designed for portable field testing where high displacements of an Exciter Head is not necessary. The 1001P HPS provides up to 1.2 GPM (5 l/m) of flow at 3,000 PSI to operate the 1100 Series Exciter Systems. The unit is air cooled and can operate on either 110V or 220V single phase power.

1201B Laboratory Hydraulic Power Supply
1201B Laboratory HPS

The 1201B Hydraulic Power Supply is designed for laboratory testing and is generally used to power the Xcite 1100 and 1200 Series Exciter Heads. The 1201B HPS provides up to 5 GPM (20 l/m) of flow at 3,000 PSI and is air cooled for ease of use in the laboratory. Power requirements are 200/220/380 or 440V, 3 phase 50/60 Hz power.

1301B Laboratory Hydraulic Power Supply
1301B Laboratory HPS

The 1301B Hydraulic Power Supply is similar in design to the 1201B HPS except its flow capacity is 15 GPM (60 l/m) at 3,000 PSI. It is generally used to power the 1300 Series Exciter Systems which require large amounts of flow due to their larger size, force and stroke capabilities. The 1301B is air cooled therefore requiring no water supply or drain in the laboratory for system cooling. Power requirements are 200/220/380 or 440V, 3 phase 50/60 Hz power.

1302C Laboratory Hydraulic Power Supply
1302C Laboratory HPS

The 1302C Hydraulic Power Supply provides up to 15 GPM (60 l/m) at 3,000 PSI of flow like the 1301B. Its main difference is that it is water cooled therefore requiring the laboratory to have both cool water supply and drain capability. It is also used to power the larger Xcite 1300 Series Exciter Systems. Power requirements are 200/220/380 or 440V, 3 phase 50/60 Hz power.

1502C Hydraulic Power Supply
1502C HPS

The 1502C Hydraulic Power Supply is designed to operate very large exciter systems requiring large amounts of hydraulic flow. It is capable of up to 30 GPM (120 l/m) of flow at 3,000 PSI. The unit is water cooled like the 1302C HPS and requires cool water supply and drain for operation. Power requirements are 380V or 440V, 3 phase 50/60 HZ power.

Model Number 1001P HPS 1201B HPS 1301B HPS 1302C HPS 1502C HPS
Flow 1.2 GPM (5 l/m) 5 GPM (20 l/m) 15 GPM (60 l/m) 15 GPM (60 l/m) 30 GPM (120 l/m)
Pressure 3,000 PSI (206 Bar) 3,000 PSI (206 Bar) 3,000 PSI (206 Bar) 3,000 PSI (206 Bar) 3,000 PSI (206 Bar)
Pump Type Constant Displacement Var. Vol/Press. Comp. Var. Vol/Press. Comp. Var. Vol/Press. Comp. Var. Vol/Press. Comp.
Motor 3 HP 10 HP 30 HP 30 HP 60 HP
Voltage 110/220 Switch Selectable 220/380/440 Specify 220/380/440 Specify 220/380/440 Specify 220/380/440 Specify
Current 20/10 Single Phase 30/17/15 A Three Phase 72/42/36 A Three Phase 72/42/36 A Three Phase 144/84/72 A Three Phase
Reservoir Capacity 5 Gal (20 l) 15 Gal (60 l) 40 Gal (160 l) 40 Gal (160 l) 120 Gal (113 l)
Reservoir Fill / Empty Pump Yes No No No No
Cooling Air/Oil Air/Oil Air/Oil Water/Oil Water/Oil
Water Requirement N/A N/A DNA 8 GPM/ 50 PSI/ 70°F max  8 GPM/ 50 PSI/ 70°F max
Oil Filtration 5 Micron Absolute 5 Micron Absolute 5 Micron Absolute 5 Micron Absolute 5 Micron Absolute
Polarized Quick Disconnects Yes Yes Yes Yes Yes
Max Ambient Temp 104°F (40°C)  104°F (40°C)  104°F (40°C)  104°F (40°C)  104°F (40°C)
Cabinet Roto-molded Plastic Metal Metal No No
Wheels No Yes Yes Yes No
Shut Down on:
        Low Oil Yes Yes Yes Yes Yes
        Over Temp Yes Yes Yes Yes Yes
        Dirty Filter No No No No No
Alarm Light on:
        Low Oil No Yes Yes Yes Yes
        Over Temp No Yes Yes Yes Yes
        Dirty Filter No Yes Yes Yes Yes
        Incorrect Phase DNA Yes Yes Yes Yes
Emergency Stop Yes Yes Yes Yes Yes
Pressure Gauge Yes Yes Yes Yes Yes
Temperature Gauge Yes Yes Yes Yes Yes
Oil Level Gauge Yes Yes Yes Yes Yes
Oil Required Mobil DTE 24/25 or Equal Mobil DTE 24/25 or Equal Mobil DTE 24/25 or Equal Mobil DTE 24/25 or Equal Mobil DTE 24/25 or Equal
Dimensions:
        Width 30 in (750 mm) 30 in (750 mm) 62 in (1550 mm) 50 in (1250 mm) 54 in (1382 mm)
        Length 30 in (750 mm) 37 in (950 mm) 44 in (1100 mm) 36 in (900 mm) 72 in (1843 mm)
        Height 36 in (900 mm) 53 in (1350 mm) 62 in (1550 mm) 50 in (1250 mm) 70 in (1792 mm)
Weight w/o Oil 265 lbs (120 kg) 860 lbs (390 kg) 2,000 lbs (909 kg) 1,500 lbs (682 kg) 2,200 lbs (1,000 kg)
20 Ft (6 m) Power Cord Yes Yes Yes Yes Yes
Manual